ATC Power Breaker Bypass Isolation Open/Closed Transition ATS

Request Info

Contact Us For Price

SPECS SUMMARY

Rating Range200-5000A
Transfer TypeBypass isolation, Closed transition
Switch TypePower Breaker
Control Power200-5000A, 2-, 3-, 4-pole
100% rated Short
Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Breaker based Bypass isolation ATS are available from 200A to 5,000A.

Specifications

Rating Range200-5000A
Transfer TypeBypass isolation, Closed transition
Switch TypePower Breaker
Control Power200-5000A, 2-, 3-, 4-pole
100% rated Short
System Voltage Application120-600 Vac 50/60 Hz
Time Withstand85,000 for 30 cycles
Withstand100 kAIC at 600V, 3 cycles
Applicable TestingCSA C22.2 No. 178 certified
UL 1008 listed up to 3200A
4000A, and 5000A UL 891 listed

Benefits and Features

  • ATC-800 microprocessor-based controller
  • True RMS voltage and frequency sensing
  • Full 30-cycle short time withstand capability
  • 30-cycle, 85 kA short-time rating on power circuit breaker
  • Multiple field programmable time delays
  • Switch position indication
  • Source availability indication
  • Source 1 and 2 auxiliary contacts
  • Programmable plant exerciser
  • System test pushbutton
  • Load shed from emergency
  • Mimic diagram
  • Safe manual operation under full load with permanently affixed operating handle
  • Drawout capabilities on both ATS, bypass portions and power switching devices completely interchangeable between ATS and bypass units

Standard Equipment

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
  • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

Optional Equipment

  • Surge suppression
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Integrated service entrance
  • Space heaters
  • Remote communications
  • Multi-meter options available
  • 2- or 4-position test switch
  • Selectable automatic or non-automatic operation
  • Open or closed transition
  • Load sequencing contacts
  • Integral overcurrent protection
  • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
  • Time delay neutral
  • In-phase transition