3512 (60 HZ) W/ Upgradable Package | 890-1250 kW Diesel Generator

Request Info

Contact Us For Price

SPECS SUMMARY

Standby Rating1250/1100 ekW
Prime Power Rating1135/1000 ekW
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 480 Volts
The 3512A generator set withUpgradeable Packaging has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Specifications

Standby Rating1250/1100 ekW
Prime Power Rating1135/1000 ekW
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating1250 ekW
Minimum Rating890 ekW
Engine Model3512A, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69 in (170 mm)
Stroke7.48 in (190 mm)
Displacement3161.03 in³ (51.8 l)
Compression Ratio13.5:1
AspirationTA
Fuel SystemMUI
Governor TypeWoodward
Length - Maximum203.5 in (5169 mm)
Width - Maximum79.3 in (2015 mm)
Height - Maximum92 in (2336 mm)
Dry Weight - Genset (minimum)22099 lb (10024 kg)
Dry Weight - Genset (maximum)22540 lb (10224 kg)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air cleaner; single element canister type with service indicator
  • Auto/start/stop control
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • kVAr-hr (total)
  • EMCP 4.2B
  • kVAr (per phase, average & percent)
  • Customer data link (Modbus RTU)
  • KVAR/PF modes, RFI suppression, min/max exciter
  • Overcurrent (50/51)
  • IVR includes reactive droop capability, 3-phase voltage sensing
  • Generator phase sequence
  • 6 programmable digital inputs
  • Engine cool-down timer
  • Limiter and exciter diode monitor
  • Over/under voltage (27/59)
  • Low coolant temperature
  • Generator set packages include Caterpillar's voltage regulator (IVR)
  • Accessory module data link
  • Low oil pressure
  • Over/under frequency (81 o/u)
  • Generator mounted - rear facing
  • Reverse reactive power (kVAr) (32RV)
  • Emergency stop
  • Lamp test
  • Overspeed
  • kVA (per phase, average & percent)
  • Operating hours
  • DC volts
  • Low coolant level
  • Programmable protective relaying functions:
  • Frequency (Hz)
  • Amps (per phase & average)
  • Environmental sealed front face
  • Failure to start (overcrank)
  • Power factor (per phase & average)
  • Controls:
  • kW (per phase, average & percent)
  • Oil pressure (psi, kPa or bar)
  • 24 Volt DC operation
  • 4 programmable relay outputs (Form A)
  • Emergency stop pushbutton
  • 2 Programmable relay outputs (Form C)
  • RPM
  • Digital indication for:
  • Engine cycle crank
  • Speed adjust
  • Coolant temperature
  • 2 Programmable digital outputs
  • Text alarm/event descriptions
  • Serial annunciator module data link
  • Communications:
  • kW-hr (total)
  • Volts (L-L & L-N)
  • Alarm acknowledge
  • Warning/shutdown with common LED indication of shutdowns for:
  • Reverse power (kW) (32)
  • High coolant temperature
  • Coolant level sensors (Not included with packages without radiator)
  • Coolant drain line with valve
  • Fan and belt guards
  • JWAC
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • Dry exhaust manifold
  • Flanged faced outlet(s)
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Internal excitation (IE) or Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • 6 Lead
  • LV
  • 60 Hz models: NEMA standard hole pattern
  • Busbar connections, top center mounted, top cable entry
  • 3 Phase brushless, Salient pole
  • Random wound
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • KVAR/PF modes
  • Exciter diode monitor
  • Caterpillar's digital voltage regulator (CDVR) includes:
  • RFI suppression
  • Reactive droop capability
  • Min / max exciter limiter
  • Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
  • Generator set packages include: Regulator (CDVR)
  • 3 Phase voltage sensing
  • Woodward 2301A isochronous governor
  • Fumes disposal
  • Lubricating oil
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Oil drain lines and valve
  • Rails - engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • 24-Volt electric starting motor
  • Battery and battery rack w/cables
  • 50 Amp Charging alternator
  • Battery disconnect switch
  • Flywheel and Flywheel housing-SAE No. 00
  • SAE standard rotation
  • RH service
  • Paint - Caterpillar yellow with high gloss black rails & radiator

Optional Equipment

  • Single stage air cleaners
  • Dual element air filters
  • 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
  • Remote custom annunicator
  • CAN2 network equipment
  • Modbus monitoring of packages
  • EMCP 4.3, EMCP 4.4
  • Local discrete I/O package
  • Vandle proof panel door
  • Cat connect
  • Load share module options
  • First local annunciator
  • Coolant
  • Water level gauge
  • Optional radiator arrangements
  • Exhaust flexible fittings
  • Industrial grade (15 db) mufflers
  • Exhaust elbows
  • Exhaust Y Adapters
  • Space heater control
  • Space heater
  • Generator conversion
  • Space heater
  • Space heater control
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • Oil level regulator
  • Lube oil
  • Primary fuel systems
  • Prelube sump pump
  • Oil level regulator
  • Gensets vibration analysis
  • PGS Test report @ 1.0 power factor
  • PKG factory test report
  • Standard genset TVA report
  • Standard engine test charge
  • Fuel consumption test
  • Generator test report
  • Standard engine test charge
  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor
  • Torsional vibration analysis
  • Generator test report
  • Protection systems
  • Ventilation system
  • Protection systems
  • Ventilation system
  • Battery chargers - 10, 20 and 35 amp
  • 24 Volt battery set - Dry
  • Battery chargers - 10, 20 and 35 amp
  • 24 Volt battery set - Dry
  • Spring type vibration isolators
  • Puck style low efficiency lsolators
  • IBC vibration isolators
  • Spring type vibration isolators
  • Pyrometer and thermocouples
  • Explosion relief valves
  • Oversize battery set
  • Jacket water heater
  • Electric starting motors
  • Jacket water heaters
  • 24 Volt dual electric starting motor
  • Starter cover
  • Barring devices
  • Breaker power connections
  • EMCP voltage and current sensing groups
  • Center post busbars
  • Electronically operated circuit breakers
  • Right hand power connections