3516B (50 HZ) W/ Upgradable Package | 2000-2500 kVA Diesel Generator

Request Info

Contact Us For Price

SPECS SUMMARY

Standby Rating2500 kVA
Prime Power Rating2275 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 415 Volts
2000 - 2500 kVA at 50 Hz Diesel Genset
The 3516B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
Q. Does this generator comply with ISO 8528 guidelines?
A. Yes, the 3516B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

Specifications

Standby Rating2500 kVA
Prime Power Rating2275 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2500 kVA
Minimum Rating2000 kVA
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69 in (170 mm)
Stroke8.46 in (215 mm)
Displacement4764.73 in (78 l)
Compression Ratio15.5:1
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Length - Maximum247.3 in (6282 mm)
Width - Maximum90 in (2286 mm)
Height - Maximum98.2 in (2494 mm)
Dry Weight - Genset (maximum)34250 lb (15535 kg)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity
  • Telecommunication Lab of China

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air cleaner; single element canister type
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Accessory module data link
  • Low oil pressure
  • 1 Programmable relay outputs (Form C)
  • Reverse power (kW) (32)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Environmental sealed front face
  • Programmable protective relaying functions:
  • kW-hr (total)
  • Auto/start/stop control
  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • EMCP 4.2B
  • 6 Customer programmable digital inputs
  • Load histogram feature
  • Emergency stop pushbutton
  • Reverse reactive power (kVAr) (32RV)
  • Customizable screens
  • Failure to start (overcrank)
  • kW (per phase, average & percent)
  • Low coolant level
  • PLC functionality
  • Communications:
  • kVAr-hr (total)
  • Engine cycle crank
  • Coolant temperature
  • kVA (per phase, average & percent)
  • Controls:
  • High coolant temperature
  • Generator phase sequence
  • Digital indication for:
  • Over/under frequency (81 o/u)
  • Number of I/O varies on options selected
  • Low coolant temperature
  • Alarm acknowledge
  • 1 Programmable digital outputs
  • Amps (per phase & average)
  • Cat connect
  • Overspeed
  • Engine cool-down timer
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • RPM
  • Power factor (per phase & average)
  • Serial annunciator module data link
  • 24 Volt DC operation
  • Overcurrent (50/51)
  • Generator mounted - rear facing
  • Over/under voltage (27/59)
  • 3 Analog inputs
  • 4 Programmable relay outputs (Form A)
  • Speed adjust
  • Text alarm/event descriptions
  • kVAr (per phase, average & percent)
  • Customer data link (Modbus RTU)
  • Frequency (Hz)
  • Volts (L-L & L-N)
  • DC volts
  • Lamp test
  • Certified standard PGS provided
  • Flanged faced outlet(s)
  • Dry exhaust manifold
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters
  • Fuel priming pump
  • Flywheel and flywheel housing - SAE No. 00
  • SAE standard rotation
  • Caterpillar yellow with high gloss black rails and radiator
  • Right hand servicing
  • Low voltage:
  • Busbar connections, right side extension box, bottom cable entry
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA standard hole pattern
  • Internal excitation (IE)
  • Random wound
  • Anti-condensation space heater
  • Winding temperature detectors
  • Form wound
  • 6 Leads
  • High voltage:
  • Medium voltage:
  • 3 Phase brushless, Salient pole
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Busbar connections, top center mounted, top cable entry
  • Parts book
  • Oil drain lines and valve
  • Fumes disposal
  • Oil filter, filler and dipstick
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool
  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery disconnect switch

Optional Equipment

  • EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom
  • Starting aids: 220V 50 Hz Jacket water heater
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
  • Starting motors: [ ] Standard [ ] Heavy duty
  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Muffler: [ ] Industrial Grade
  • Battery charger: [ ] 10A [ ] 20A [ ] 35A
  • Single element filter
  • Dual element air cleaner
  • Coolant
  • Standard ambient ATAAC radiators
  • Water level switch gauges
  • Standard ambient radiators
  • Optional installed ATAAC radiators
  • Optional installed radiators
  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves
  • Temperature rise (over 40�C ambient): [ ] 150�C [ ] 125�C [ ] 105�C [ ] 80�C
  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
  • Power Termination: Busbar, Circuit breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Y Adapters
  • Tier 4 clean emissions module
  • Clean emission parts
  • Exhaust offset
  • Elbows
  • Tier 4 clean emission MOD Kits
  • Flexible fittings
  • Tier 4 dosing cabinet
  • Mufflers
  • Flanges
  • Flange and exhaust expanders
  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter
  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Generator conversion
  • Space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostat for space heater
  • Alternator air cleaner
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Pyrometer and Thermocouples
  • Prelube pumps
  • Lube oil in standard sump
  • Oil level regulator
  • IBC vibration isolators
  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • Left side power connections
  • Rear power connections
  • Ground cables between generator and terminal box
  • 2700 Frame, four lead, four terminal
  • Neutral ground connections
  • Low voltage Circuit breakers
  • Center post busbars
  • Right side power connections
  • Torsional vibration analysis reports
  • PGS Test report @ 0.8 power factor
  • Standard engine test charge
  • Generator set fuel consumption test
  • OSHPD Certification
  • PGS Test report @ 1.0 power factor
  • Generator test report
  • Fuel consumption test
  • IBC Certification
  • Canadian Standards Association certification
  • Jacket water heaters
  • Electric starting motors
  • Starter cover
  • Air pressure regulator
  • Engine barring device
  • Air starting motors
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 Amp Battery chargers
  • Platinum, Gold and Silver coverage