SPECS SUMMARY

Maximum Rating715 kVA
Minimum Rating550 kVA
Emissions/Fuel StrategyLow Fuel, China Nonroad III Emis Stds
Voltage380 to 415 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Maximum Rating715 kVA
Minimum Rating550 kVA
Emissions/Fuel StrategyLow Fuel, China Nonroad III Emis Stds
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Prime
Engine ModelC18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore5.71 in (145 mm)
Stroke7.2 in (183 mm)
Displacement1106.36 in³ (18.13 l)
Compression Ratio14.5:1
AspirationAir to Air Aftercooled
Fuel SystemElectronic unit injection
Governor TypeAdemâ„¢A4
Length - Maximum162.4 in (4135 mm)
Width - Maximum78.3 in (1989 mm)
Height - Maximum75 in (1906 mm)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Turbocharger
  • Light duty air cleaner
  • Aftercooler core
  • Air cleaner
  • Exhaust flange outlet
  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guard
  • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator
  • Standard 8 hour open set fuel tank
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Matched to the performance and output characteristics of Cat engines
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated voltage regulator (IVR)
  • A Frame generator - IP21 protection
  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Power center, IP22
  • Matched to the performance and output characteristics of Cat engines
  • Cat electronic governor (ADEM A4)
  • GCCP Genset Controller
  • Lubricating oil
  • Oil drain valves
  • Rubber vibration isolators
  • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
  • 24 Volt battery with rack and cables
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Industrial, residential, critical mufflers
  • Dual element air cleaner
  • Single element air cleaner
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • Padlockable circuit breaker device
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Power terminal strip
  • Shunt trip for IEC breaker
  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • Local & remote annunciator modules
  • Load share module
  • Remote monitoring software
  • EMCP (4.2) (4.3) (4.4)
  • Digital I/O module
  • Oil temperature displays
  • GCCP 1.5
  • Volt free contact
  • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
  • Local alarm modules
  • Remote annunciator module
  • Local alarm horn
  • Low coolant temperature alarm
  • Radiator duct flange
  • Oversize batteries
  • Jacket water heater
  • Battery chargers
  • Heavy duty starting system
  • Charging alternator
  • Sound attenuated enclosures
  • Manifold and turbocharger guards
  • Engine mounted muffler
  • 8 and 10 inch elbow kits
  • 8 and 10 inch GP flanges
  • 10, 25 and 35 end in / end outmufflers
  • Integral - Dual wall fuel tank base
  • Manual fuel transfer pump
  • Fuel transfer system
  • LC frame generator
  • Permanent magnet excitation (PMG)
  • LC frame oversize generators
  • Space heaters
  • A Frame oversize generator
  • A Frame CIP generator
  • Ingress protection
  • LC frame CIP generator
  • Single or dual wall integral fuel tanks
  • UL 2200 package
  • Enclosures: Sound attenuated, weather protective
  • EU Certificate of Conformance (CE)
  • Integral & sub-base UL listed dual wall fuel tanks
  • Narrow, wide or skid base
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • CSA Certification
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • Automatic transfer switches (ATS)
  • Single or dual wall sub-base fuel tanks
  • Manual sump pump
  • Jacket water heaters
  • 5 Amp Battery charger
  • Battery disconnect switch