C3.3 (60 HZ) | 27-60 kW Diesel Generator

Request Info

SPECS SUMMARY

Minimum Rating27.0 ekW
Maximum Rating60.0 ekW
Emissions/Fuel StrategyEU Stage II & R96/EUIIIa
Voltage110 to 480 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Minimum Rating27.0 ekW
Maximum Rating60.0 ekW
Emissions/Fuel StrategyEU Stage II & R96/EUIIIa
Voltage110 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Prime
Engine ModelCat® C3.3
Bore4.1 in (105 mm)
Stroke5 in (127 mm)
Displacement201.4 in³ (3.3 l)
Compression Ratio17.25:1, 19.25:1
AspirationTurbocharged
Fuel SystemDirect Injection
Governor TypeMechanical
Length - Maximum43.9 in (1115 mm)
Width - Maximum38.2 in (970 mm)
Height - Maximum53.6 in (1361 mm)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air cleaner; light duty with disposable element
  • Air cleaner; light duty with disposable element
  • EMCP 4.1
  • EMCP4.1 control panel
  • Radiator and cooling fan with guards
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve
  • Radiator and cooling fan with guards
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Tower panel, IP22, bottom cable entry
  • 12 leads
  • IP23 Protection
  • Voltage regulator (single phase sensing)
  • Segregated low voltage (AC/DC) wiring panel
  • 12 leads
  • IP23 Protection
  • Tower panel, IP22, bottom cable entry
  • Mechanical and electrical governing system - model dependant
  • Mechancial governing system - model dependant
  • Lubricating oil
  • Oil drain line with valve
  • Oil drain line with valve
  • Lubricating oil
  • Termination points for coolant and lube oil drain lines
  • Includes lifting provision and drag points
  • Captive linear vibration isolators between base and engine-generator
  • includes lifting provisions and termination points for coolant
  • Captive linear vibration isolators between base and engine-generator
  • 12V Battery with rack & cables
  • Engine and alternator pre-paint, Caterpillar yellow
  • Engine and alternator pre-paint, Caterpillar Yellow

Optional Equipment

  • Alternator removal options
  • LC frame alternator
  • Permanent magnet
  • Anti-condensation heater
  • R frame auxilliary winding
  • LC frame alternator with coastal protection
  • Pad-lockable breaker device
  • 4 Pole circuit breaker to 250A
  • Volt free contacts
  • Control panel heater
  • Voltage adjust potentiometer
  • Speed adjust potentiometer
  • Earth leakage (2 wire only)
  • Battery charger
  • Panel mounted audible alarm
  • Overload shutdown via breaker
  • Earth fault (2 wire only)
  • Emergency stop with key
  • Coolant heater
  • Low coolant temperature alarm
  • low coolant level shutdown
  • European Upgrade to STD set for "CE"
  • Global Certification for CIS
  • Sound attenuated level 2 enclosure CE
  • Sound attenuated level 1 enclosure (GALV)
  • CEE for sockets for enclosure
  • Socket blanking plate
  • Rental pack (CAE only)
  • Open set narrow tankbase
  • Compact skidbase for open sets
  • Low fuel level alarm
  • Low fuel level shutdown
  • Bunded fuel tank
  • Skidbase for CALG enclosure sets
  • High fuel level alarm
  • Electronic governor
  • Residential Silencer
  • Silencer installation kit
  • External single point lift - enclosure
  • Battery removal
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Packing case, compact set
  • Stone guards / rad trans flange
  • Packing case, canopied set