C4.4 (60 HZ) | 36-100 kW Diesel Generator

Request Info

Contact Us For Price

SPECS SUMMARY

Maximum Rating 100 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy Non Regulated, EU Stage II
Voltage 220 to 480 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Maximum Rating 100 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy Non Regulated, EU Stage II
Voltage 220 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime
Engine Model C4.4, In-line 4, 4-cycle diesel
Bore 4.13 in (105 mm)
Stroke 5 in (127 mm)
Displacement 268.5 in (4.4 l)
Compression Ratio 18.2:1
Aspiration Turbocharged
Fuel System Electronic (adjustable)
Governor Type Adem™A4
Length - Maximum 75.8 in (1925 mm)
Width - Maximum 44.1 in (1120 mm)
Height - Maximum 53.6 in (1361 mm)

Benefits and Features

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements
  •     
  • Image may not be a representative of actual product

        
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

        
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  •     
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  •     
  • Each generator set package is tested before leaving the Caterpillar facility
  •     
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

        
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  •     
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air cleaner; light duty with disposable element
  • Air cleaner
  • Package mounted radiator
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guards
  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Exhaust flange outlet
  • GCCP 1.3
  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump
  • Segregated low voltage (AC/DC) wiring panel
  • Voltage regulator (single phase sensing)
  • Matched to the performance and output characteristics of Cat engines
  • 12 Leads
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • Mechanical and electrical governing system - model dependent
  • Lubricating oil
  • Oil drain line with valve
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
  • Rubber vibration isolators
  • 24V battery with rack and cables
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • Engine and alternator pre-paint, Caterpillar yellow
  • 24 volt starting motor
  • Batteries

Optional Equipment

  • Industrial, residential, critical mufflers
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • Anti-condensation heater
  • 3 phase sensing
  • Permanent magnet excitation (PMG)
  • R Frame auxilliary winding
  • Quadrature droop kit
  • LC Frame alternator with coastal insulation protection
  • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • GCCP 1.3
  • Load share module
  • Digital I/O module
  • Remote monitoring software
  • Local & remote annunciator modules
  • Coolant heater
  • Low coolant level shutdown
  • Low coolant temperature alarm
  • Earth fault (2 wire only)
  • GCCP 1.3
  • Volt free contacts
  • Emergency stop with key
  • Battery charger
  • Panel mounted audible alarm
  • Control panel heater
  • Speed adjust potentiometer
  • Voltage adjust potentiometer
  • Earth leakage (2 wire only)
  • Overload shutdown via breaker
  • Jacket water heater
  • Charging alternator
  • Heavy duty starting system
  • Battery chargers
  • Oversize batteries
  • Sound attenuated Level 2 enclosure
  • Sound attenuated Level 1 (galv)
  • Rental pack - CAE rental option only
  • Upgrade to STD set for CE
  • Compact skidbase for open set
  • Low fuel level alarm
  • Low fuel level shutdown
  • Bunded fuel tank
  • Open set narrow tankbase
  • Skidbase for CALG enclosure sets
  • High fuel level alarm
  • Single or dual wall sub-base fuel tanks
  • EU Certificate of Conformance (CE)
  • CSA Certification
  • Single or dual wall integral fuel tanks
  • Automatic transfer switches (ATS)
  • Narrow, wide or skid base
  • UL 2200 package
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • EEC Declaration of Conformity
  • Integral & sub-base fuel tanks
  • Certification for CIS
  • Battery removal
  • Electronic governor
  • Industrial silencer
  • Silencer installation kit
  • External single point lift - enclosure
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Packing case - compact set
  • Stone guards/rad trans flange
  • Packing case - canopied set