SPECS SUMMARY

Maximum Rating450 ekW
Minimum Rating450 ekW
Emissions/Fuel StrategyEPA Stationary Emergency
Voltage480 to 600 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Maximum Rating450 ekW
Minimum Rating450 ekW
Emissions/Fuel StrategyEPA Stationary Emergency
Voltage480 to 600 Volts
Frequency60 Hz
Speed1800 RPM
Duty CycleStandby
Engine ModelCat® C15 In-line 6, 4-cycle diesel
Bore5.4 in (137 mm)
Stroke6.8 in (171 mm)
Displacement928 in³ (15.2 l)
Compression Ratio16.1:1
AspirationTurbocharged Air-to-Air Aftercooled
Fuel SystemMEUI
Governor TypeADEM™A4
Length - Maximum189.6 in (4815 mm)
Width - Maximum64.2 in (1630 mm)
Height - Minimum80.1 in (2034 mm)
Height - Maximum101.7 in (2584 mm)
Dry Weight - Genset (minimum)8172.5 lb (3707 kg)
Dry Weight - Genset (maximum)10238.3 lb (4644 kg)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • UL 2200 Listed
  • ULC Certification Available

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Aftercooler core
  • Turbocharger
  • Air cleaner - Non canister, disposable
  • Thermostats and housing
  • Blower fan and fan drive with guards
  • Radiator, package mounted
  • Coolant drain valve
  • Jacket water pump, gear driven, centrifugal
  • Radiator sight gauge
  • Exhaust manifold - dry
  • Fuel priming pump
  • Integral tank base, 24 hours, UL142
  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Engine fuel transfer pump
  • Fuel cooler
  • Complete system designed & built at ISO 9001:2000 certified facilities
  • Factory tested to design specifications at full load conditions
  • All protective devices and control functions simulated and checked
  • IP23 Protection
  • Voltage regulator (single phase sensing)
  • Easy access to AVR and terminals
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Terminal box, IP22 RHS facing, bottom cable entry
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • 6 Leads
  • Insulation system, Class H
  • Cat electronic governor (ADEM A4)
  • Fumes disposal to front of radiator
  • Oil filter, spin on
  • Lubricating oil, CK-4 (10W-30)
  • Shallow oil pan
  • Oil cooler
  • Oil filler and dipstick
  • Oil drain with valve
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
  • Safety shutoff - Low oil pressure
  • Safety shutoff - Overspeed
  • Safety shutoff - High water temperature
  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator
  • Vibration damper
  • Parts book
  • Lifting eyes

Optional Equipment

  • Air cleaner (Non canister disposable)
  • Overfill prevention valve
  • Wide Base - Skid
  • Audio & visual fuel alarm (@90% fuel level)
  • Integral tank base, 24 hours, UL142
  • Fuel tank pill pipe & lockable cap
  • 5 Gallon Spill Containment
  • Industrial, residential, critical mufflers
  • 400A LSI
  • 400A LS/I
  • 800A LSI
  • Auxiliary contacts
  • 600A LS/I
  • 1200A LSI
  • 600A LSI
  • 1200A LS/I
  • 800A LS/I
  • Volt free contacts
  • 100A Load center
  • Product link remote monitoring hardware
  • Twist release, Red button emergency stop
  • 16 -light NFPA 99/110 Annunciator
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Audible alarm Gp
  • Ground fault relay
  • E-Stop
  • AC & DC Source lights
  • Sound attenuated Level 2 enclosure (White)
  • Anti-condensation heater
  • Oversize and premium generators
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Permanent magnet excitation (PMG) generator
  • Space heater
  • Manifold and turbocharger guards
  • Flexible exhaust connection
  • 8" Muffler - 25 dBA attenuation
  • Standard battery set: 1000 CCA, 90 amp/hr.
  • Oversize battery set, 1400 CCA, 200 amp/hr
  • Battery charger (UL Certified)
  • Jacket water heater
  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • UL2200 Certification
  • CSA Certification
  • Extended Service Coverage
  • Generator test report
  • CSA Certification
  • UL 2200 package
  • Manual sump pump
  • Narrow skid base - replaces standard fuel tank base