SPECS SUMMARY

Minimum Rating600 ekW
Maximum Rating600 ekW
Emissions/Fuel StrategyU.S. EPA Certified
Voltage480 to 600 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Minimum Rating600 ekW
Maximum Rating600 ekW
Emissions/Fuel StrategyU.S. EPA Certified
Voltage480 to 600 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby
Engine ModelCat® C18 ATAACTM In-line 6, 4-cycle diesel
Bore5.71 in (145 mm)
Stroke7.2 in (183 mm)
Displacement1106.3 in³ (18.1 l)
Compression Ratio14.5:1
AspirationAir to Air Aftercooled
Fuel SystemElectronic unit injection
Governor TypeElectronic ADEM™ A4
Length - Maximum196.1 in (4980 mm)
Width - Maximum73.4 in (1865 mm)
Height - Maximum100.9 in (2563 mm)

Benefits and Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

M-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL 2200 Listed
  • ULC Certification Available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Turbocharger
  • Air cleaner - Non-Canister, Disposable
  • Aftercooler core
  • Radiator sight gauge
  • Thermostats and housing.
  • Coolant drain valve.
  • Jacket water pump, gear driven, centrifugal
  • Blower fan and fan drive with guards
  • Radiator, Package mounted.
  • Exhaust manifold; dry
  • Fuel cooler
  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Integral Tank Base, 24 Hrs, UL142
  • Engine fuel transfer pump
  • Fuel priming pump
  • Complete system designed & built at ISO 9001:2000 certified facilities
  • Factory tested to design specifications at full load conditions
  • All protective devices and control functions simulated and checked
  • 6 leads
  • Voltage regulator (single phase sensing)
  • Easy access to AVR and terminals
  • Insulation, Class H
  • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)
  • Terminal Box, IP22 RHS Facing, Bottom Cable Entry
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • IP23 protection
  • Cat Electronic Governor (ADEM A4)
  • Oil filler and dipstick.
  • Shallow oil pan.
  • Oil filter, spin on.
  • Oil cooler
  • Lubricating Oil, CK-4 (10W-30)
  • Oil drain with valve.
  • Fumes disposal to front of radiator.
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
  • Safety Shutoff - High water temperature
  • Safety Shutoff - Overspeed
  • Safety Shutoff - Low Oil Pressure
  • 24V,45 amp charging alternator.
  • 24-volt electric starting motor.
  • Parts Book
  • Vibration damper.
  • Lifting Eyes

Optional Equipment

  • Air Cleaner (Non-Canister Disposable)
  • Audio & Visual Fuel Alarm (@90% Fuel Level)
  • Integral Tank Base, 24 Hrs, UL142
  • 5 gallon Spill Containment
  • Overfill Prevention Valve
  • Fuel Tank Fill Pipe & Lockable Cap
  • Wide Base - Skid
  • 400A LSI
  • Auxiliary Contacts
  • 400A LS/I
  • 800A LSI
  • 600A LSI
  • 1200A LS/I
  • 800A LS/I
  • 600A LS/I
  • 1200A LSI
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Ground Fault Relay
  • 16 -light NFPA 99/110 Annunciator
  • Volt Free Contacts
  • Twist Release, Red Button Emergency Stop
  • 100A Load Center
  • Product Link Remote Monitoring hardware
  • Audible Alarm Gp
  • Earth (Ground) fault relay
  • Volt free contact
  • Remote E-Stop button
  • Discrete I/O module
  • Annunciators box
  • Local annunciator
  • 8" Muffler - 25 dBA Attenuation
  • Flexible Exhaust Connection
  • Manifold & Turbocharger Guards
  • Space Heater
  • Permanent Magnet Generator
  • Jacket Water Heater
  • Standard Battery Set: 1000 CCA, 90 amp/hr.
  • Battery Charger (UL Certified)
  • Oversize Battery Set, 1400 CCA, 200 amp/hr.
  • Extended Service Coverage
  • Generator Test Report
  • CSA Certification
  • UL2200 Certification
  • Tool set
  • Single LSI motorised circuit breaker
  • Single LSI motorised Circuit Breaker
  • Auxiliary contacts
  • Neutral bar (208V)
  • E-Stop
  • Sound Attenuated Level 2 Enclosure (White)
  • AC & DC Source Lights
  • Sound attenuated enclosure
  • Coolant heater
  • Stone guards
  • Jacket water heater with pump
  • Audio & visual fuel alarm
  • Integral 8 hr tank base
  • Oversize battery set
  • Standard battery set
  • 5 Amp battery charger
  • Battery disconnect switch
  • CSA 22.2
  • UL2200 Listed
  • Seismic
  • Manual sump pump