DE715 GC (50 Hz) | 715 kVA Diesel Generator

Request Info

Contact Us For Price

SPECS SUMMARY

Maximum Rating715 kVA
Minimum Rating715 kVA
Emissions/Fuel StrategyNon Regulated
Voltage380 to 415 Volts
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Maximum Rating715 kVA
Minimum Rating715 kVA
Emissions/Fuel StrategyNon Regulated
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby
Engine ModelC15 In-line 6, 4-cycle diesel
Bore5.4 in (137 mm)
Stroke6.8 in (171 mm)
Displacement928 in³ (15.2 l)
Compression Ratio16.1:1
AspirationTurbocharged Air-to-Air Aftercooled
Fuel SystemEUI
Governor TypeAdem™A4
Length - Maximum131 in (3328 mm)
Width - Maximum60.6 in (1540 mm)
Height - Maximum86.1 in (2187 mm)
Dry Weight - Genset (maximum)8613 lb (3907 kg)

Benefits and Features

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Air cleaner
  • Mechanical governor
  • A Frame standard alternator
  • Package mounted radiator
  • Single wall 8 hour fuel tank
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump
  • 3 Pole Circuit breaker
  • Neutral earth link
  • 24 Volt battery with rack and cables
  • Air cleaner; light duty with disposable element
  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • IP23 Protection
  • Lubricating oil
  • Oil drain line with valve
  • Captive linear vibration isolators
  • Lifting provision and drag points
  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated voltage regulator (IVR)
  • Optional LC Frame generator - IP23 Protection
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Rubber vibration isolators
  • Cat electronic governor (ADEM A4).
  • Oil cooler
  • Oil drain valves
  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • 24 Volt battery with rack and cables
  • Engine and alternator pre paint, Caterpillar yellow
  • Engine and alternator pre paint, Caterpillar yellow

Optional Equipment

  • Speed and Voltage adjust potentiometers
  • PLG 4G/3G/Ethernet
  • Annunciator
  • Emergency E-Stop
  • Industrial, residential, critical mufflers
  • Cat GC enclosure
  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • 4 Pole Circuit breaker
  • Auxiliary contacts
  • Padlockable circuit breaker
  • Battery charger
  • Wet battery
  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • Space heater
  • AVR
  • Dual wall 8 hour fuel tank
  • Single wall 8 hour fuel tank with spill containment
  • Low fuel level shutdown
  • Low and high fuel level alarms
  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Dual wall fuel tank base
  • Permanent magnet excitation (PMG) generator
  • Oversize A Frame generator
  • Ingress protection
  • LC frame CIP generator
  • LC frame generator
  • Oversize LC frame generator
  • CIP A Frame generator
  • Space heaters
  • Battery chargers
  • Heavy duty starting system
  • Charging alternator
  • Oversize batteries
  • Jacket water heater
  • Industrial silencer
  • 10 dBA Attenuation silencer
  • Engine mounted muffler
  • Manifold and turbocharger guards
  • End in/end out mufflers - 10, 25 and 35 dBA attenuation
  • 6 and 8 inch elbow kit
  • Flexible exhaust fittings
  • 6 and 8 inch flange GP
  • Single stage air filter
  • Dual element air filter
  • EU Certificate of Conformance (CE)
  • EAC Certification
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Narrow, wide or skid base
  • Automatic transfer switches (ATS)
  • Single or dual wall sub-base fuel tanks
  • EEC Declaration of Conformity
  • CSA Certification
  • UL 2200 package
  • Integral & sub-base UL listed dual wall fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Single or dual wall integral fuel tanks
  • 3, 4, 5 and 10 Years
  • High ambient sound attenuated enclosures
  • Manual sump pump
  • Narrow skid base - replaces standard fuel tank base
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • 5 Amp single Battery charger
  • Battery disconnect switch
  • Jacket water heater