CG132B-16 | 400kW-800kW Gas Generator


Contact Us For Price
SPECS SUMMARY
Maximum Continuous Rating | 800 kW @1.0pf |
Fuel Type | Natural Gas, Biogas |
Maximum Electrical Efficiency | 43.5% / 42.6% |
Maximum Standby Rating | 800 kW |
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.
Specifications
Maximum Continuous Rating | 800 kW @1.0pf |
Fuel Type | Natural Gas, Biogas |
Maximum Electrical Efficiency | 43.5% / 42.6% |
Maximum Standby Rating | 800 kW |
Frequency | 50 / 60 Hz |
RPM | 1500 / 1800 rpm |
Engine Model | CG132 |
Displacement | 2135.8 in³ (35 l) |
Aspiration | TA |
Bore | 5.2 in (132 mm) |
Stroke | 6.3 in (160 mm) |
Length | 165 in (4200 mm) |
Width | 70 in (1780 mm) |
Height | 85 in (2150 mm) |
Dry Weight - Genset | 17691 lb (8070 kg) |
Benefits and Features
Lower Operating Costs
- Optimized engine components mean the CG132 uses up to 50% less lubricating oil than competing generator sets, which means more money stays in your company's pockets
Smaller footprint
- The CG132 uses nearly 50% less space than similar system
- Less space means lower installation costs
Cat Total Electronic Management System
- Temperature and pressure monitoring for each cylinder
- Anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes
Flexible Fuel Usage
- Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases
Standard Equipment
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
- TPEM (Total Plant & Energy Management System)
- Flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- ANSI/DN customer flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
- grid code generator
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Busbar connections
- Anti-condensation space heater
- 3-phase sensing and KVAR/PF control
- Winding temperature detectors
- 24V starting motors
- Battery disconnect switch
- Crankshaft vibration damper and guard