CG132B-16 | 700kW-1000kW Gas Generator

Efficiency at a New Level from Caterpillar | Cat® CG132B Gas Generator Set Efficiency at a New Level from Caterpillar | Cat® CG132B Gas Generator Set
Request Info

Contact Us For Price

SPECS SUMMARY

Continuous Rating1000 ekW @1.0pf
Fuel TypeNatural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency41.50%
Frequency50 Hz
The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.<br>
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 1000kW and comes with the Total Plant and Energy Management (TPEM) system.

Specifications

Continuous Rating1000 ekW @1.0pf
Fuel TypeNatural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency41.50%
Frequency50 Hz
RPM1500 rpm
Engine ModelCG132B
Displacement2135.8 in (35 l)
AspirationTA
Bore5.2 in (132 mm)
Length165 in (4200 mm)
Stroke6.3 in (160 mm)
Width70 in (1780 mm)
Height85 in (2150 mm)
Dry Weight - Genset17791 lb (8070 kg)
Natural Gas Rating1000

Benefits and Features

Lower Operating Costs

  • Optimized engine components mean the CG132 uses up to 50% less lubricating oil than competing generator sets, which means more money stays in your company's pockets

Smaller footprint

  • The CG132 uses nearly 50% less space than similar system
  • Less space means lower installation costs

Cat Total Electronic Management System

  • Temperature and pressure monitoring for each cylinder
  • Anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes

Flexible Fuel Usage

  • Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases

Standard Equipment

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder
  • TPEM (Total Plant & Energy Management System)
  • Flange connections for JW inlet and outlet
  • Electrical jacket water and aftercooler coolant pump
  • Jacket water and SCAC thermostats
  • flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Exhaust waste gate for the CG132B-16
  • Closed crankcase ventilation system
  • PEARL/Low resistence exhaust system
  • Pre-chamber spark plugs
  • Independently controlled cylinder monitoring and ignition system
  • Electronic fuel metering valve
  • Anti-condensation space heater
  • Reactive droop
  • 3-phase sensing and KVAR/PF control
  • Busbar connections
  • grid code generator
  • closed-coupled generator result in no torque transmission to the base frame
  • Reactive droop
  • Winding temperature detectors
  • 24V starting motors
  • Battery disconnect switch
  • Crankshaft vibration damper and guard

Optional Equipment

  • Air cleaner with precleaner
  • Mounting stand
  • CHP skid
  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands