SPECS SUMMARY
Continuous Rating | 400 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency | 43.1% / 42.1% |
Frequency | 50 / 60 Hz |
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.
Specifications
Continuous Rating | 400 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency | 43.1% / 42.1% |
Frequency | 50 / 60 Hz |
RPM | 1500 or 1800 rpm |
Engine Model | CG132-8 |
Displacement | 1067.9 in³ (17.5 l) |
Aspiration | TA |
Bore | 5.2 in (132 mm) |
Length | 122 in (3100 mm) |
Stroke | 6.3 in (160 mm) |
Width | 70 in (1780 mm) |
Height | 85 in (2150 mm) |
Dry Weight - Genset | 12610 lb (5720 kg) |
Benefits and Features
High Efficiency, Lower Operating Costs
- Highest efficiency in its output class
- Up to 42.5% improved electrical efficiency
- Reduced vibration and stress on components
Low installation, Building and Operating Costs
- Compact design with integrated fuel tanks for daily refilling
- Lower setup costs than comparable engines
- Reduced investment costs through expanses product scope and TPEM digital control system
- Long maintenance intervals (up to 80,000 hours)
- Optimized oil management
Optimized Lubrication Consumption
- Consumes less than 0.1g/kW of oil
- Up to 66% lower lubricant consumption than comparable models
- Longer lubricant change (up to 4,000 hours) and oil change intervals
Standard Equipment
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
- TPEM (Total Plant & Energy Management System)
- flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
- Independently controlled cylinder monitoring and ignition system
- Electronic fuel metering valve
- Pre-chamber spark plugs
- Anti-condensation space heater
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Busbar connections
- 3-phase sensing and KVAR/PF control
- grid code generator
- 24V starting motors
- Battery disconnect switch
- Crankshaft vibration damper and guard
Optional Equipment
- CHP skid