SPECS SUMMARY

Continuous Rating1380 ekW @1.0pf
Fuel TypeNatural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency45.00%
Maximum Standby Rating1380
State-of-the-art components providing more power: the compact design, a focus on a wide range of applications and highest efficiency values of its class make sure of that. Managed by a smart and secure control system, the new CG170B series offers the optimal balance between profitability and reliability.

Specifications

Continuous Rating1380 ekW @1.0pf
Fuel TypeNatural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency45.00%
Maximum Standby Rating1380
Frequency50 Hz
RPM1500 rpm
Engine ModelCG170B-12
AspirationTA
Bore6.7 in (170 mm)
Stroke7.7 in (195 mm)
Length200 in (5080 mm)
Width67 in (1710 mm)
Height86 in (2190 mm)
Dry Weight - Genset28440 lb (12900 kg)

Benefits and Features

  • Up to 45% electrical efficiency with Natural Gas
  • 43.6% electrical efficiency with biogas
  • Electrical output up to 1,380 kWel
  • Reduced vibration and stress on components

  • Compact design that delivers up to 18% more power output at the same size as its predecessor
  • Long maintenance intervals (up to 80,000 hours)
  • Available in different applications, such as natural gas, biogas, wellhead- and propane gas operation
  • Maximum flexibility through different engine variants

  • Consumes ~0.15g/kWh
  • Reduced lube oil temperature through better cooling performance
  • Savings of up to 3,000 liters of lube oil per year compared to comparable gensets

Standard Equipment

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder
  • TPEM (Total Plant & Energy Management System)
  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Electrical jacket water and aftercooler coolant pump
  • flange connections for JW inlet and outlet
  • Exhaust waste gate for the CG170B-12
  • PEARL/Low resistence exhaust system
  • Closed crankcase ventilation system
  • Pre-chamber spark plugs
  • Electronic fuel metering valve
  • Independently controlled cylinder monitoring and ignition system
  • Reactive droop
  • closed-coupled generator result in no torque transmission to the base frame
  • Winding temperature detectors
  • Busbar connections
  • grid code generator
  • Anti-condensation space heater
  • 3-phase sensing and KVAR/PF control
  • 24V starting motors
  • Battery disconnect switch
  • Crankshaft vibration damper and guard

Optional Equipment

  • CHP skid
  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands