Contact Us For Price
SPECS SUMMARY
| Power Range | 3640 - 3520 ekW |
| Frequency | 50 / 60 Hz |
| Emissions | EPA Tier 2, IMO II |
| Speed | 900 - 1000 rpm |
Specifications
| Power Range | 3640 - 3520 ekW |
| Frequency | 50 / 60 Hz |
| Emissions | EPA Tier 2, IMO II |
| Speed | 900 - 1000 rpm |
| Aspiration | Turbocharged-Aftercooled |
| Bore | 11 in (280 mm) |
| Stroke | 11.8 in (300 mm) |
| Displacement | 13546 in³ (222 l) |
| Governor Type | Electronic |
| Fuel System | EUI |
| Length | 316.5 in (8040 mm) |
| Width | 77.2 in (1961 mm) |
| Height | 155 in (3937 mm) |
| Weight - Estimated | 25000 lb (11340 kg) |
| Compression Ratio 50 Hz | 13.1 |
| Compression Ratio 60 Hz | 13:1 |
| Minimum Rating | 3520 ekW (4400 kVA) |
| Maximum Rating | 3640 ekW (4550 kVA) |
| Engine Model | V 12, 4-Stroke-Cycle Diesel |
Benefits and Features
CAN J1939 data link Waterproof connectors, Maintenance-free, Backup ECU for redundant governing
Load feedback, Programmable droop, Adjustable gain, Adjustable fuel/air ratio control, Histograms of engine operation, Cat Messenger display presents diagnostics and other engine parameters
Engine speed, Boost pressure, Throttle position, Fuel consumption rate, Inlet manifold temperature, Diagnostic codes and events, Configuration, Desired engine speed, Battery voltage, Engine load, Lifetime totals — engine hours, fuel burned, idle fuel, idle hours, Trip totals — average fuel rate, idle fuel, idle hours, engine hours, fuel burned, trip reset
Interfaces with standard Cat® Marine Monitoring System (PLC in Price List), Provides visual indication of ECU functionality, Accepts 4 — 20 mA or PWM remote throttle speed input, Marine alarm and protection
“Drop-in” installation, No threaded fuel connections, High pressure inside injector only, Does not require double wall fuel lines or leak collection device, Injector synchronization not required
Standard Equipment
- LH and RH service availability
- Aftercooler — fresh water, corrosion resistant coated (air side)
- Crankcase breathers, top mounted
- Air inlet adapter - Straight / 90 degree / 35 degree
- Dual turbochargers, rear-mounted, engine oil lubricated
- Dual Caterpillar ADEM A4 Electronic Engine Control Modules
- Rigid Wiring Harness
- Aftercooler / oil cooler and jacket water pumps (gear driven)
- Engine coolant water drains
- Single Circuit / Separate Circuit Aftercooler
- Dry, gas tight, exhaust manifold
- Turbo speed sensors - overspeed protection
- Fuel transfer pump, gear driven
- Duplex Fuel filters
- Electronically Controlled Unit Injectors
- CAT Alarm & Protection System
- Oil pump, gear driven
- 3 element oil cooler, engine mounted
- Duplex centrifugal oil filter - engine mounted
- Prelube pump - air / electric
- Cylinder pressure relief valves
Optional Equipment
- Exhaust manifold shielding - soft
- SOLAS shielding
- Front and rear oil pan drains
- Wet sump
- SOLAS shielding
- Oil mist detector
- Cylinder pressure relief valves